30KVA Online High Frequency Modular UPS

30KVA Online High Frequency Modular UPS
Product Detailed
1. 30KVA Modular UPS 2. N+X redundancy modularization 3. Strong load capacity 4. High reliable design 5. SNMP network card

30KVA Online High Frequency Modular UPS

MP series modular UPS is regarded as the leading digital power supply. It concentrates the most advanced technological achievements in power electronic industry and automatic control field with 10 patents, greatly improving the power supply reliability, availability and maintainability of the key equipments.

MP series modular energy conservation green UPS unified the traditional tower UPS technical characteristic and the modern engine room modularization demand, while realizes modular design, has guaranteed system's redundant reliability.

MP series provides all kinds of specification power module as well as the cabinet system, the user may carry on the flexible disposition according to the load demand. The single cabinet may realize the 100kVA capacity, after parallel, may realize the 200kVA capacity disposition.

N+X redundancy modularization design

Each power module in the system is designed for hot plug online, which is convenient for customers' installing, maintenance as well as promotion dilatancy demands. Each power module is the self-contained guidance, non-simple point breakdown risk. The single power module will quit automatically when it fails and not affect other modules working as well as system's normal power supply.  Intelligent battery management plan

Each power module built-in independent 3200W digitization high efficiency battery charger, so 200kVA modular UPS system may provide 32kW charge ability. The chargers are DSP digital control to ensure the remarkable battery management performance. Compare with partial factories methods-hanging directly battery with the direct-current bus bar, MP series modulation UPS uses the independent battery discharge converter to reduced the single unit battery quantity greatly, besides realize the remarkable charging and discharging management and control as well as lengthen battery's service life

Strong load capacity

MP series modulation UPS has the remarkable load adaptation performance, providing strong load capacity to all kinds of linearity and misalignment load. Each power module and the cabinet system can provide the load ability compares favorably with any tower system, thus has guaranteed this serial products in various professions application scope.

Intelligent protect plan

MP series modulation UPS power module and system use the hardware and the software dual protection design proposals. Regarding any voltage, current, thermal properties, and short circuit possibly appear abnormal for the power module and system, it can protect promptly and effectively, thus guarantee system's security and reliability.

System Advantages

♦ UPS system modularization design, N+X redundancy, hot plug online and promotion dilatancy

♦ Strong load applicability and ability and strong power system applicability

♦ Green energy conservation power: complete machine efficiency over 95%, input power factor more than 0.99, and input current harmonic less than 3%

♦ Power module double DSP controller disposing, module independent control, and ‘0’ single point failure risk

♦ Rectification, inverter, charge, and discharge realize the DSP numerical control completely.

♦ Use the integration to seal the IGBT module, not the separate component to improve the reliable of power module and system greatly.

♦ The frontal maintenance, provides the high and low coil in way, convenient user wiring.

♦ Large screen man-machine contact surface, rich information content

♦ Independent charge system, formidable charge ability, and consummation battery management plan

♦ Entire digitized module parallel technology, extremely good circulation target

♦ It can be installed close to other equipment to save the space.

♦ Redundancy intelligent frequency controlled fans with low nose and energy conservation

♦ The system cabinet interior integration electrical power distribution system installment facilitates extremely, and saves the user investment

♦ Remarkable generator match performance.

♦ It can start by battery DC (cold start), convenient for operation.

♦All circuit wafers use the water-stain-dust-proof craft.

System Options

♦ SNMP network card

♦ Lightning-protection module

♦ Battery temperature compensator

♦ SMS alarm apparatus

♦ Dust screen 

 

Specification

Capacity10~200KVA
Main input
Input voltage380V/400V/415Vac
Input frequency50/60Hz
Power factor> 0.99
Current distortion factorTHD < 3%
Voltage range-40% ~ +25%
Frequency range40~70Hz
Battery
Battery voltage±384Vdc
Charge power20%* System power
Charge voltage precision±1%
Bypass
Bypass voltage380V/400V/415Vac
Voltage range-50% ~ +20%
Overload capacity150%, long-term working
150%< Load <180%, working time > 1 min
Load >180%, working time > 100ms
Output
Output voltage380V/400V/415V
Voltage precision±0.5% (balanced load), ±1% (unbalanced load)
Voltage distortion factorTHD<1% (linear load), THD<3% (non-linear load)
Power factor0.8
3 Phase precision120°±0.5°
Peak value ratio3:01
Overload capacity110%, bypass after one hour
125%, bypass after 10min
150%, bypass after 1min
>150%, bypass after 200ms
System
System efficiencyNormal mode: 95%
Economic mode: 99%
Efficiency in battery mode95%
DisplayLCD+LED, touch screen + keyboard
Protection gradeIP20
Communication interfaceRs232, Rs485, dry contact, SNMP card, EPO, generator connector
ConnectionSupport top and bottom coil in
Working temperature0~40°C
Storage temperature-25°C~70°C
Relative humidity0~95% (no condensation)
Noise<55dB
Weight10KVA Power modulePM10KVA: 14Kg
6 Module cabinet180Kg (MP010~MP060)
10 Module cabinet200Kg (MP010~MP100)
Dimension(W×D×H)10KVA Power module480×500×88mm
6 Module cabinet600×800×1600mm (MP010~MP060)
10 Module cabinet600×800×2000mm (MP010~MP100)
20 Module cabinet10 Module cabinet × 2 (Parallel) (Max. MP200)